EAVE GUTTER SPLICE
Layout the gutter assemblies before installation on the steel building roof. Start and finish the gutter ends as shown on next page.
Lift the gutter assembly into position under the edge of the roof panels and temporarily clamp the back flange of panel to the gutter. Position the back face of the gutter assembly flush against the panel cap trim and position its ends flush with the exterior face of the rake wall. Fasten the gutter’s back flange to the underside of the roof panel with the lap fasteners, as shown. Check that the lap fasteners are securely engaged into the gutter’s back flange.
Align the outer edge of the gutter straight and level. Use a string line to assure that the gutter is straight Install the general steel gutter straps and fasten to the roof panel with stitch screw and fasten the gutter’s outer flange to the end of the gutter strap with a pop rivet, as shown.
NOTE:
Workers should always wear gloves when handling flashing and follow all OSHA safety recommendations. Never install any material if quality or appropriateness is in question!
Rake Trim and Peak Box Installation >>