TECHNICAL DATA
Applicable Standards:
• Model Building Codes:
– CABO, BOCA, ICBO, SBCCI, ICC
• Material Standards:
– ASTM C 991 Type I
– 202-96 (Rev. 2000)
Fire Resistance:
• Fire Hazard Classification:
– UL 723, ASTM E 84, NFPA 255
Max. Flame Spread Index: 25
Max. Smoke Developed Index: 50
– CAN/ULC-S102-M88
Metal Building Insulation 202-96
Walls Roofs
• Non-combustible:
– ASTM E 136
Meets requirements
Physical/Chemical Properties:
• Thermal Resistance:
– ASTM C 518 and/or ASTM C 177
at 75°F (24°C) mean temperature.
• Acoustical Performance:
– See the tables on front and below.
• Water Vapor Sorption:
– ASTM C 1104
No greater than 5.0% by weight.
• Corrosiveness:
– ASTM C 665
Meets requirements for steel,
copper and aluminum.
• Odor Emission:
– ASTM C 1304
Pass
• Fungi Resistance:
– ASTM C 1338
Pass Test
Quality Assurance: Was the first fiber glass insulation manufacturer to have its manufacturing plants, R & D center and corporate headquarters registered to ISO 9001-2000 standards.

INSTALLATION
The vapor retarder on Metal Building Insulation 202-96 should be installed towards the conditioned spaces in the building. The insulation is normally applied over or between the structural members of the building and held in place by the covering sheets or insulation support system. When using high R-value systems, it is recommended that the cavity between the exterior metal sheet and the faced fiber glass insulation should be completely filled.